Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Full dent. sci ; 7(26): 11-18, abr. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: lil-786841

ABSTRACT

Este trabalho descreve um caso clínico de implante imediato associado ao uso de biomateriais para preservação do volume alveolar pós-extração. Foram utilizados neste procedimento matriz mineralizada bovina na apresentação de bloco e folha laminada de titânio para promoção do selamento alveolar. Quando observados os cuidados de avaliação do defeito, seleção e indicação dos materiais regenerativos, as respostas de formação e regeneração óssea são bastante surpreendentes. Os produtos utilizados e a técnica cirúrgica aplicada demonstraram ser eficientes na manutenção de volume pós-extração e regeneração do alvéolo.


This paper describes a case of immediate implant associated with the use of biomaterials to preserve alveolar volume after extraction. Foralveolar sealing bovine mineralized matrix in block presentation and titanium foil were used in this procedure. When aspects such as defect assessment, selection and indication of regenerative materials are properly considered, the responses of bone formation and regeneration are quite amazing. The utilized products and the surgical technique used have proven to be effective preserving alveolar volume postextraction and for alveolar ridge regeneration.


Subject(s)
Humans , Male , Aged , Dental Implants , Surgical Procedures, Operative/methods , Bone Regeneration/physiology , Bone Transplantation , Biocompatible Materials , Brazil , Radiography, Dental/instrumentation , Tomography, X-Ray Computed
2.
Full dent. sci ; 7(25): 10-15, jan.2016. ilus
Article in Portuguese | LILACS | ID: lil-790072

ABSTRACT

A crescente utilização de implantes dentários levou a indústria a desenvolver desenhos de componentes específicos para melhoria na capacidade da osseointegração, mas também no desenvolvimento de uma vedação biológica; isto é, um selamento de tecido mole ao redor da parte transmucosa como também da crista óssea após extração dental. A folha laminada de titânio não absorvível indicada como auxiliar na neoformação óssea atua como barreira biológica ou como lâmina totalmente impermeável, com propriedade em excluir a possibilidade de competição e invaginação dos tecidos moles sobre os enxertos e defeitos ósseos...


The increasing use of dental implants has led the industry to develop specific components designs to improve the osseointegration capacity, as well as the development of a biological seal (sealing of soft tissue around the transmucosal part and the bone crest after tooth extraction). The non-absorbable titanium foil is indicated as an aid for bone formation, acting as a biological barrier or as a totally impermeable membrane, that excludes the possibility of competition and invagination of the soft tissues over the graft and bone defects...


Subject(s)
Humans , Female , Middle Aged , Biocompatible Materials/chemistry , Osseointegration , Surgical Procedures, Operative/methods , Titanium/chemistry , Radiography, Dental/instrumentation
3.
Full dent. sci ; 4(13): 44-51, out.-dez. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681672

ABSTRACT

Os tratamentos através do uso da osseointegração possuem indicação e contraindicações específicas. Em alguns casos, as alterações ao redor dos alvéolos advindas de extrações dentárias modificam significativamente a espessura e a altura do rebordo, especialmente quando a perda do dente é decorrente de um trauma dentário, envolvimento periodontal ou a parede vestibular do rebordo é perdida durante a extração. Esses tipos de deficiências ósseas no rebordo podem dificultar ou impossibilitar o uso de certas técnicas de implantes dentários devido ao insuficiente volume ósseo para abrigar implantes de dimensões adequadas. A utilização de uma técnica incorreta pode acarretar um resultado protético inadequado, tanto pela forma estética quanto pela funcionalidade. Este estudo tem por objetivo revisar a literatura científica relacionada à técnica de expansão cirúrgica de rebordo alveolar, também conhecida como “Split Crest”, e demonstrar um caso clínico


Treatments through the use of osseointegration have specific indications and contraindications. In some cases, the changes around the alveoli arising from dental extractions significantly alter the thickness and height of the ridge, especially when tooth loss is a result of dental trauma, or periodontal involvement of the buccal wall edge is lost during extraction. These types of deficiencies in the bony ridge may hamper or prevent the use of certain techniques for dental implants due to insufficient bone volume to harbor implants of adequate dimensions. Using the wrong technique can lead to inadequate prosthetic result both in form and aesthetics for functionality. This study aims to review the scientific literature related to the technique of surgical expansion of the alveolar ridge, also known as “Split Crest, and demonstrate a case report


Subject(s)
Humans , Male , Adult , Surgery, Oral/methods , Dental Implants , Osseointegration , Osteotomy/methods , Tomography
4.
ImplantNews ; 9(1): 79-84, 2012. tab
Article in Portuguese | LILACS, BBO | ID: lil-642667

ABSTRACT

Este trabalho de revisão da literatura teve por objetivo explicar o fenômeno da osteoindução, dando ênfase aos avanços no uso das proteínas ósseas morfogenéticas na reparação do tecido ósseo. As BMPs são da superfamília das TGF-β e estão envolvidas em quimiotaxia, mitose e diferenciação de células mesenquimais no tecido ósseo. Esses fatores de crescimento, muito estudados na atualidade, têm como principal membro osteoindutor a BMP-2 e podem ser purificados (obtidos através de osso animal) ou recombinados (através de engenharia genética) para que juntamente com um carreador, ou sozinhos, sejam usados em sítios onde se deseja a formação de novo tecido ósseo. Concluiu-se que as BMPs são uma alternativa viável para o aumento de rebordo alveolar visando a reabilitação com implantes endósseos, sendo necessários mais estudos para assegurar sua eficácia como uma alternativa ao uso de osso autógeno


This aim of this literature review is to explain the osteoinduction principle, giving emphasis on bone morphogenetic proteins for bone tissue repair. BMP’s derived from TGF-β superfamily is involved into chemotaxis, mitosis, and mesenchymal stem cell differentiation at bone tissue level. These growing factors are represented by BMP-2 and can be purified (through animal origin) or recombined (through genetic engineering techniques), to be used with or without a carrier in sites where new bone formation is required. We concluded that BMP’s are an alternative to ridge alveolar augmentation for oral implant rehabilitation, being necessary further studies to assure their efficacy compared to autogenous bone grafts.


Subject(s)
Bone Morphogenetic Proteins , Bone Regeneration , Intercellular Signaling Peptides and Proteins
5.
Full dent. sci ; 1(2): 112-116, Aug. 15, 2010.
Article in Portuguese | LILACS, BBO | ID: lil-605593

ABSTRACT

A osseoindução tem sido aplicada por diversos meios com o objetivo de tratamento de defeitos ósseos e oferecer uma reabilitação adequada ao paciente. As matrizes formadas por osso bovino de granulação média é indicada para se usar como material de implante osseoindutor para aumento de volume de rebordo. Um protocolo para execução da reparação de atrofia severa da mandíbula foi realizado. Osso bovino de granulação média foi aglutinado com sangue do próprio paciente para formar uma matriz mineral com poros adequados para a proliferação endotelial. Com exames radiográficos pode-se observar que o osso bovino promoveu uma quantidade de osso neoformado o suficiente para encobrir todo o comprimento dos implantes. Esse osso novo favoreceu um aumento em sentido vertical, na altura do rebordo alveolar do osso retromolar. Apesar de ter uma neoformação menos acelerada quando comparada com o osso humano liofilizado esta terapêutica deve ser de conhecimento e se possível do domínio do implantodontista para poder aplicá-la quando necessária, para otimizar a colocação de implantes.


Osseoinduction has been applied in bone defects treatment and provide adequate rehabilitation to the patient. The bovine bone matrix, formed by the average grain, has been used as material for implant osseoinductor in alveolar ridge augmentation. A protocol for implementation of the severe atrophy jaw repair was performed. Bovine bone granulation average was agglutinated with patient’s own blood to form a matrix with pores mineral appropriate for endothelial proliferation.With X-rays can be observed that the bovine bone promoted a number of neoformed bone enough to cover the entire length of the implants. This new bone increased in the vertical direction, at the edge of the alveolar bone. Despite having a slower neoformation when compared to the human bone, professionals should know it and dominate it to apply it when necessary and to optimize the placement of implants.


Subject(s)
Cattle , Alveolar Ridge Augmentation/methods , Alveolar Ridge Augmentation , Bone Matrix , Dental Implants , Biocompatible Materials , Bone Resorption/diagnosis , Bone Regeneration/physiology , Tooth Socket , Bone Transplantation/rehabilitation , Radiography/methods , Radiography , Tomography/methods
6.
ImplantNews ; 8(2): 221-226, 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-599202

ABSTRACT

A forma do implante, mais especificamente o perfil de suas roscas, pode influenciar significativamente na distribuição de tensões sobre o tecido ósseo. Dessa forma, fica evidente a importância da realização de estudos laboratoriais que permitam a verificação do comportamento dos implantes quando a carga incide sobre diferentes formatos de roscas. Este trabalho teve como objetivo analisar, por meio da análise fotoelástica, a influência dos formatos das roscas dos implantes na distribuição de tensões à estrutura de suporte de um modelo experimental. Foram construídos dois corpos de prova em resina fotoelástica, sendo que no modelo I foram colocados dois implantes de roscas trapezoidais e no modelo II foram colocados dois implantes com roscas triangulares com os seus respectivos componentes. Primeiramente, foi feita a aplicação de carga vertical de 6,4 kgf, a seguir, de 11,2 kgf e por último uma carga aplicada de 16 kgf, simulando uma sobrecarga no modelo I e no modelo II. Nos dois modelos (II e II) houve distribuição homogênea das franjas isocromáticas no terço cervical, médio e apical, porém, no modelo I a intensidade das franjas foi maior. Conclui-se que não houve diferença nos locais de distribuição das tensões entre os modelos I e II, mas a intensidade das franjas isocromáticas no modelo I mostra que existe maior compressão ao redor do implante de roscas trapezoidais.


The design of a dental implant thread shape can be decisive on bone stress distribution. Thus, basic research is fundamental to identify its mechanical behavior when the load is applied on different types of thread formats. This study analyzed, by photoelastic techniques, the influence of the screw-thread formats in the stress distribution on the experimental model. Two photoelastic resin models were fabricated: model 1 consisted of trapezoidal-shaped and model 2 of triangle-shaped screw-thread implants with its respective components. Sequential loads of 6.4kgf, 11.2kgf, and 16kgf (overload) were applied in both groups. Uniform distribution of isochromatic fringes was verified at the cervical, middle and apical thirds of both models, with fringe intensity being higher in the model 1. One can conclude that greater compression was found around the trapezoidalshaped, screw-thread implants.


Subject(s)
Dental Implants , Dental Stress Analysis , Prostheses and Implants , Materials Testing
7.
Full dent. sci ; 1(4): 379-383, jul.-set. 2010. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-642935

ABSTRACT

A presente pesquisa teve como objetivo avaliar a translucidez das cerâmicas restauradoras sobre pilares de alumina e zircônia. Foram confeccionados corpos – de – prova com formato dental e foi criada uma escala visual para a avaliação das tomadas fotográficas e para a realização do estudo. Essa escala marcou Alta translucidez, Média translucidez e Baixa translucidez. Os corpos de prova foram submetidos à luz de alta intensidade e foram obtidas imagens, as quais foram analisadas por contagem de quadrantes, sendo os mesmos calculados qualitativa e quantitativamente. O sistema que apresentou maior translucidez, e ausência total de bloqueio de luz foi o alumina. O sistema zircônia foi o que apresentou resultados mais altos e equilibrados de média translucidez.


This study aimed to evaluate the translucency of the restorative ceramic on alumina and zirconia abutments. Samples were prepared shaped in tooth, creating a visual scale for evaluation of photographic shots and for the study. This scale marked translucency High, Medium and Low translucency. The specimens were subjected to high-intensity light and images were obtained, which were analyzed by counting the quadrants, and they are calculated qualitatively and quantitatively. The system showed more translucent, and total absence of light was the alumina. The zirconia system showed the highest results and balanced medium translucency.


Subject(s)
Esthetics, Dental , Dental Implants/methods , Dental Materials/chemistry , Zirconium/chemistry , Data Interpretation, Statistical
8.
Full dent. sci ; 1(1): 14-21, 2009.
Article in Portuguese | LILACS, BBO | ID: lil-602580

ABSTRACT

O objetivo do trabalho foi avaliar a percepção sensorial e tátil após instalação de prótese sobre implante dental, comparando com dentes naturais e reabilitações protéticas convencionais. Na osseopercepção os sinais sensoriais são oriundos de mecanoreceptores localizados na articulação temporomandibular, músculos, mucosa, epitélio e periósteo, considerando também a existência da plasticidade do Sistema Nervoso Central em se adaptar as mudanças sugerindo uma possível recuperação sensorial e motora no caminho do impulso nervoso gerado na região perimplantar. Os resultados desse estudo demonstraram existir sensibilidade sensorial e tátil e essa é similar aos analisados para os indivíduos com dentes naturais. As próteses fixas ou removíveis implantossuportadas têm uma recuperação do limiar tátil interoclusal a níveis aproximados para o de dentes naturais. A presente pesquisa sugere que a prótese implantossuportada representa uma alternativa de tratamento adequada para restabelecer a habilidade de percepção tátil do ponto de vista fisiológico, portanto, favorecendo a qualidade de vida dos que utilizam próteses.


The objective was to evaluate the sensory and tactile perception after installation of dental prosthesis on implants compared to natural teeth and prosthetic conventional rehabilitation. Researchers suggest that in osseo-perception the sensory signals from mechanoreceptors are located in the temporomandibular joint, muscles, mucosa, epithelium and periosteum, also considering the existence of the plasticity of the central nervous system to adapt to changes, suggesting a possible recovery in sensory and motor path of nerve impulse generated in the perimplant region. The results showed there sensory sensitivity and tactile and it is similar comparing to individuals with natural teeth. This research suggests that the implant-supported prosthesis is an alternative treatment appropriate to restore the ability of tactile perception of physiological point of view, therefore, improving the quality of life using prosthesis.


Subject(s)
Humans , Dental Implants , Osseointegration
9.
ImplantNews ; 2(3): 251-255, maio-jun. 2005. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-428119

ABSTRACT

A estabilidade inicial em Implantologia é citada como condição indispensável para o sucesso da osteointegração. Sabe-se que além da estabilidade mecânica, torna-se de fundamental importância a estabilidade biológica para total fixação de implantes. Analisando a estreita relação entre preparo dos alvéolos ósseos e aquecimento, em diferentes regiões, este estudo torna-se de total importância no que se refere a quantidade de calor gerado durante o ato de perfuração. A análise dos resultados demonstra, com precisão, a quantidade de calor gerado na primeira fresagem, e os cuidados a serem respeitados, principalmente com relação a diferentes regiões ósseas


Subject(s)
Male , Female , Humans , Dental Implantation, Endosseous , Dental Instruments , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL